top of page
Front of station.png

Fire Station 85 – New Construction 

Fire Station 85

Status: Complete

Completion Date:

July 2020

Role:

QA QC / Schematic Design / Design Development / Construction Documentation / Fire Department Coordination

Delivery Method:

CMAR

This project was a ground up build of a fire station for HFD. It was a modified design from the standard protype to support trail response needs and increased fitness areas. There were significant site logistics issues with it being placed where a COH dog park was and also significant drainage coming off the back of the mountain onto the site.

Project Photos

The station has three bays to support an engine , ladder , rescue, and a small garage to suppot the trail response vehicle.

IMG_3215.JPEG

Open concept kitchen with stainless steel counter tops. Also strategically positioned acoustic dampening materials used to avoid sound reverberations

Watershed from the mountains had to be diverted to the rear of the station.

IMG_3196.JPG

Expanded gym area with roll up door to utilize rear app bay ramp for PT activities

Converted the space into 14 individual dorm rooms with individual alerting and individual climate controls.  Created six individual bathrooms with two strategically located alongexit pathway to the apparatus bay. Reworked office an utility areas to provide for more functionality and increase capabalties.  A laundry room was created to allow for laundeering of station uniforms and bedding and keep seperation from items going into the app bay and returning to the station. A dedicated utility room was also created to keep ice machine and water softner oout of the apparatus bay.

IMG_3216.JPEG

Dorm hallway with straight shot to app bay to reduce turnout time and collisions walking around corners

IMG_3224.JPEG

Lobby with secure access to Fire Station living quarters

2019.06.17 - CoH FS 85 at Hidden Falls (5).JPG

Site with the dog park removed and before station construction began

Aerial view.jpg
IMG_1212.JPEG

Watershed from the mountain had to be diverted to behind the station. 

IMG_1826.JPEG

Station positioning was critical to support ladder truck turning radius and allow for drainage control

Pictured left - Coverted a small conference room and open lobby space into six new offices to support expanding staff needs for the FTC

Pictured below - Converted a group style shower and typical bathroom stalls into completely enclosed shower rooms, bathrooms and also an ADA compliant bathroom and shower

Operational Impacts

Response Times not reduced during construction

Minimized turnout times through optimized phasing and positioning of crews during renovation processes

Improved Facilities

Provided multiple washers and dryers so crews would not use turnout extractors for laundering non PPE items

Staffing Efficiency

Designed to maximize operational workflow and allow for crew continuity.  The crew office was intentionally left open to the kitchen and dining table to allow for better crew cohesion

System Resiliency

The building was reinforced to meet current code standards and ensure it was reslient to any impacts

Future Growth Flexibility

The Fire Training Center and the Fire Station both lacked enough workspace areas in todays heavily dominated computing environment.  Extra offices and workspaces were created to alleviate this issue

bottom of page